Rms-technologies R325P DRIVER Instrukcja Użytkownika Strona 13

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 12
USB485 Converter Card
Figure 6.3
7. COMMAND TABLES
The R325PE can also be used as an indexer with closed loop controls. Basic controller commands can be used
but users cannot store programs to the unit. This unit is commonly used with a user-created GUI or PLC’s that
can communicate commands via ASCII and serial port.
Basic Configuration Commands
Function
Query/Command
Code
Value
Minimum
Maximum
Default
Load Defaults
N
LD
None
-
-
-
Save Data
N
SD
None
-
-
-
Module Address
Q/C
MA
Numeric
65 (A)
90 (Z)
65 (A)
Baud Rate
Q/C
BR
Numeric
9600
57600
9600
Table 7.1
Axis Configuration Commands
Function
Query/Command
Code
Value
Minimum
Maximum
Default
Acceleration
Q/C
AC
Numeric
1
250
10
Hold Current
Q/C
HI
Numeric
0
3000
300
Hold Timeout
Q/C
HT
Numeric
100
5000
500
Min. Velocity
Q/C
MV
Numeric
250
15,000
250
Percent Fast Decay
Q/C
PF
Numeric
0
3
2
Run Current
Q/C
RI
Binary
300
3000
1000
Read Switches
Q
RS
Numeric
0
1023
-
Step Resolution
Q/C
SR
Numeric
1
256
8
Start Velocity
Q/C
SV
Numeric
250
15,000
1000
Velocity Limit
Q/C
VL
Numeric
250
50,000
15,000
Zero Position
C
ZP
None
-
-
-
Table 7.2
RMS Technologies Page 13 Version 1.01
R325PE Single Axis Closed loop Driver/Indexer Manual 5/29/2013